TDS MONITOR ADJUSTMENT - continued .
WARNING
High voltages in this equipment can cause serious injury or death. When applying power
during a test, take proper measures to ensure safety of personnel. Never work on
electrical equipment unless there is another person nearby who is familiar with the
operation and hazards to the equipment.
CAUTION
Use extreme care to avoid contacting the fuse or control circuitry other than trimmer
calibration screws. Failure to do so could result in damage to the equipment.
(7)
Start power source (power source manual) and apply electrical power to ROWPU (TM 10-4610-241-10).
(8)
Push and hold calibration test switch SW1 (13) in the up position. Multimeter should indicate + 10 volts.
(9)
If multimeter does not indicate + 10 volts, adjust main calibration trimmer R9 (14) to obtain correct indication.
(10)
Push and hold calibration test switch SW1 (13) in the up position. Adjust front panel meter trimmer R25 (15) to
obtain full scale indication (2000) on panel meter (5).
(11)
Shut off electrical power to ROWPU (TM 10-4610-241-10). Shut down power source (power source manual).
(12)
Remove multimeter leads from TB2-7 (11) and TB2-6 (12).
(13)
Position panel meter (8) on circuit box (9) and press in four fasteners (7).
d.
Close cover (2) on TDS monitor and tighten two screws (1).
e.
Remove TDS monitor that is damaged or cannot be adjusted (TM 10-4610-241-10). Send TDS monitor to Direct
Support Maintenance.