TM 10-4610-241-24
TO 40W4-13-42
2-30.
THREADED PIPE REPLACE - continued
(b) Install adapter (18) on threaded pipe (22) and install gasket (20) in adapter.
(c) Connect union nut (18) to active component (19).
(d) Complete installation, using one or more steps of this Paragraph. If required install color code tape.
(5) Install threaded pipe on other threaded pipe or active component (i.e check valve or gage) as follows:
(a) Clamp pipe (23) or active component in vise.
NOTE
Be sure to wrap tape in direction of threads.
(b) Wrap male pipe threads with teflon tape.
(c) Screw pipe (23) into threads of active component (23) with pipe wrench.
2-139