TM 10-4610-241-24
TO 40W4-13-42
2-29.
GROOVED PIPE (PIPE SECTIONS, ELBOWS, FITTINGS, ETC) REPLACE -continued.)
b.
Installation.
(1)
Position pipe support (15) on floor of ROWPU.
(2)
Lubricate gaskets (13) and position on pipe (1).
(3)
Position grooved pipe (1) in unit. Slide gaskets (13) over pipe joint.
(4)
Place clamp halves (12) over gasket (13) and install two bolts (11) and nuts (10). Repeat for joint at other end of
pipe.
NOTE
Be sure to wrap tape in same direction as threads.
(5)
Apply anti-seize tape to male threads of adapter (9).
(6)
Install adapter (9) and connect sensing lines (8) to adapter (9). Tighten nut (7)
NOTE
Some grooved pipe sections are held in place with retaining straps. Install retaining straps as required.
(7)
Install insulation tape (6), retaining strap (5), two lockwashers (4), flat washers (3), and screws (2).
(8)
Install color code tape (14) as required.
(9)
Operate ROWPU and test for leaks (TM 10-4610-241-10).
2-134