TM 10-4610-241-24
TO 40W4-13-42
2-54.
CABLE ASSEMBLY (R.O. PUMP) REPLACE - continued.
c.
Installation.
(1)
If removed, install elbow (26) on conduit box (24).
(2)
If removed, position gasket (25) and conduit box (24) on motor (27) and install four lockwashers (23)
and screws (22).
(3)
Position nut (20), seal ring (19) and seal (18) on lug end of cable assembly (:21).
(4)
Feed four wires of cable assembly (21) through elbow (26) into conduit box (24), providing about 6
inches of slack.
(5)
Position seal (18) in elbow (26) and seal ring (19) in nut (20) and screw nut onto elbow.
NOTE
Ground wire insulation may be green, or GREEN may be written on black ground
wire.
(6)
Secure ground wire (17) (green) to conduit box (24) with screw (16).
NOTE
There are three wire bundles in conduit box. All are assembled the same.
One is shown, the others are similar.
Wire sets must consist of wires as marked at removal. If wire markings are
lost or illegible, use the following table for electrical connections. Wire
insulation may actually be black on all three wires. If this is the case, color
code is written on insulation:
SET 1
SET 2
SET 3
T1
T2
T3
Black
White
Red
(7)
Position flatwasher (13), two wire lugs (14) (as marked), lockwasher (12) and nut (11) on screw (15)
and tighten nut. Repeat for other two sets.
(8)
Using electrical tape (10), wrap bare metal parts on each wire set (8).
(9)
Using twine (9), secure electrical tape (10) on each wire set (8) and position three wire sets in
conduct box (24).
(10)
Position gasket (7) and conduit box cover (6) on conduit box (24) and install four lockwashers (5) and
screws (4).
(11)
Secure cable assembly with clamp (3), lockwashers (2) and screws (1) to motor mounting
plate (29).
(12)
Operate ROWPU and check for proper operation (TM 10-4610-241-10).
2-212