3-20. TDS MONITOR REPAIR - continued.
c.
Assembly.
(1)
Install gasket (18), adapter (17) and nut (16) on TDS monitor.
(2)
Position sleeve (22) on cable assembly (23).
(3)
Position nut (21), seal ring (20) and seal (19) on cable assembly (23).
(4)
Route cable assembly thru adapter (17) and into TDS monitor.
(5)
Making sure wire ends of cable assembly reach terminal board (6), slide sleeve (22) up to extend
approximately 1/2 inch into TDS monitor, fit seal (19) into adapter (17), slide seal ring (20) and nut (21) up
to adapter and screw nut onto adapter.
(6)
Install gasket (11), adapter (10) and nut (9) on TDS monitor.
(7)
Position nut (14), seal ring (13) and seal (12) on cable assembly (15).
(8)
Route cable assembly (15) thru adapter (10) into TDS monitor.
(9)
Making sure, wire ends of cable assembly (15) reach terminal board (5), fit seal (12) into adapter (10), slide
seal ring (13) and grip nut (14) up to adapter and screw grip nut onto adapter.
NOTE
To insure correct operation of TDS monitor, be sure to connect wires as tagged. If tags
are lost or illegible, connect cable (15) as follows:
Cable Assembly (15)
Connection Point
Black
TBI-1
White
TB1-2
Green
TB1-3
(10) Using small blade, flat tip screwdriver, depress wire retainers (7) on terminal board (15) and connect wires
of cable as tagged during disassembly. If tags are lost or illegible use color code.
NOTE
To insure correct operation of TDS monitor, be sure to connect wires of cable assembly
(23) as tagged. If tags are lost or illegible, connect wires as follows:
Cable Assembly (15)
Connection Point
Black
TB2-1
White
TB2-2
Red
TB2-3
Green
TB2-4
Bare
TB2-5
3-152