TM 10-4610-241-24
TO 40W4-13-42
3-49.
CONTROL BOX ASSEMBLY REPAIR.-continued.
f.
Assembly.
(1)
Toggle switches.
NOTE
There are 11 toggle switches. The number of wires attached to each switch may vary
depending on use. All switches are installed the same. One is shown.
(a) Position lockring (14) and switch body (13) in cutout on control box (5).
(b) Apply RTV sealant to lockring (14) to seal the switch.
(c) Install lockwasher (12) and mounting nut (11).
NOTE
Wire tags may be lost or become illegible. If this occurs, consult electrical
interconnection diagrams, Appendix F, or information plate on door of junction box for
connection information.
(d) Connect wires (10) as tagged, or use electrical interconnection diagram and secure with two screws (9).
3-286