TM 10-4610-241-24
TO 40W4-13-42
3-49.
CONTROL BOX ASSEMBLY REPAIR.-continued.
(5)
Electrical relays K10 and K11.
(a) Install sleeving (39) on wires (38) to be soldered to relays (44 and 43).
NOTE
Wire tags may be lost or become illegible. If this happens, consult electrical
interconnection diagrams, Appendix F, or data plate on door of junction box for
connection information.
(b) Solder wires (38) to pins on relays (44 and 43) as tagged or use electrical interconnection diagrams.
(c) Position relays (43 and 44) on bracket (48) and install four lockwashers (42) and nuts (41).
(d) Position bracket (48) on cover (6) and install two screws (47), lockwashers (46), and nuts (45).
3-290