TM 10-4610-241-24
TO 40W4-13-42
3-51.
WIRING HARNES, W2 REPAIR-continued.
b.
Cleaning.
Clean Wiring harness with a damp rag.
c.
Inspection.
Inspect wiring harness in accordance with TM 43-0158/TO 1-1A-15 (Air Force).
d.
Test.
Test wiring harness for continuity and shorts, using table on previous page as a guide.
e.
Repair.
(1)
Replace lockwashers.
(2)
Replace all damaged and unserviceable components.
(3)
Repair wiring harness in accordance with TM 43-0158/TO 1-lA-15 (Air Force).
f.
Installation.
(1)
Position gasket (6) and connector (5) of wiring
harness (20) in cutout on control panel (21)
and install four screws (4), washers (3)
lockwashers (2) and nuts (1).
(2)
Select wire, marked E2 on wiring harness
(21) and secure to ceiling of control box along
with other ground wires (13) with screw (14),
lockwasher (15), flatwasher (11), lockwasher
(10) and nut (9).
(3)
Connect wires (8) to switches, lights and
terminal
boards
in
accordance
with
information stamped on wires and secure with
screws (7).
(4)
If removed, install clamps (19) and secure
with screws (18), lockwashers (17) and nuts
(16).
(5)
Secure harness (20) to existing wiring with
tiedown straps as required.
3-297