ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
0002 00
DESCRIPTION AND THEORY OF OPERATION
EQUIPMENT DESCRIPTION AND DATA
EQUIPMENT DATA
Performance:
Water Source
Water
Production
(minimum)
Surface water containing up to 20,000 mg/l TDS and up to 150 NTU @ 32 to 95 F
1500 GPH
Ground water containing up to 2500 mg/l TDS @ 32 to 95 F
1500 GPH
Ground water containing over 2500 mg/l TDS and up to 150 NTU, @ 50 to 95 F
1200 GPH
Normal Seawater containing 35, 000 mg/l TDS, 32 to 95 F
1200 GPH
Seawater containing 45,000 mg/l TDS, 50 to 95 F
1200 GPH
Seawater containing 45,000 mg/l TDS, 32 to 50 F
1000 GPH
Seawater containing 60,000 mg/l TDS @ 77 F
950 GPH
Dimensions:
MC-TWPS: 13'9" L x 6' " H x 7'2" W
A-TWPS: 20' L x 8' H x 8' W
Weight:
MC-TWPS: 9,552 lbs fully packed out for deployment less fuel (w/out extended capability modules)
A-TWPS: 22,588 lbs. fully packed out for deployment less fuel
Basic Metals:
MF System Piping: 70-30 Copper-Nickel
RO System:
Low Pressure Piping: 70-30 Copper-Nickel
High Pressure Piping: 254 SMO
Product Piping: 316L Stainless Steel
Air System Piping: 316 Stainless Steel
Skid: 6061 Aluminum
Flat Rack Frame: ASTM A500 Carbon Steel
Operating Temperature Range: -25 F to 120 F (cold weather kit required if operating temperature is
below 32 F)
Storage temperature range: - 28 F to 160 F
Maximum water temperature: 100 F
Maximum slope of unit when deployed for operation: 2 degrees front to back, 1 degrees side to side
Power source requirement: 416 VAC, 3 phase, 60 Hz, 60 kW
Fuel Type (60 kW TQG): DF2, DFA, JP8
Fuel Capacity (60 kW TQG): 43 gallons
END OF WORK PACKAGE
0002 00-37/38 BLANK