ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0009 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
PREPARATION FOR USE AND INSTALLATION INSTRUCTIONS
COLD WEATHER SET-UP OPERATION UNDER UNUSUAL CONDITIONS
A-04
A-05
P-2
PROJECTED P-1 LOCATION
2 X 50 D-HOSE
2 X 50 D-HOSE
2 X 10 S-HOSE
Figure 12. P-1 Pump to P-2 Pump Configuration Deployment.
2. Connect the raw water adaptors and hoses as follows:
WARNING
Health hazard. Do not attempt to use product water hoses to handle raw water or
raw water hoses to handle product water. When installed with the proper adaptors
as directed, the hoses cannot be interchanged. Failure to observe this warning
and mixing hoses could cause contamination of water resulting in serious illness.
a. Collect the following hoses and adaptor assemblies:
1) Two to four 2 in. x 50 ft., green-banded raw water discharge hoses.
2) One 2 in. x 10 ft., green-banded raw water suction hose.
3) Adaptor assemblies A-04 and A-05.
b. Inspect the gaskets in the female ends of the hoses. Replace any damaged or missing
gaskets.
c. Connect, as needed, one or two 2 in. x 50 ft., green-banded discharge hoses to the
suction inlet of Motor-Driven Pump P-2 and lay out to the location marker for Diesel-
Driven Pump P-1.
d. Attach Adaptor A-04 to the discharge outlet of the motor-driven pump.
e. Connect, as needed to reach the MF feed tank location, one or two 2 in. x 50 ft., green-
banded discharge hoses to Adaptor A-04 at the discharge of Motor-Driven Pump P-2.
f. Connect Adaptor A-05 to the end of the discharge hose that is coming from P-2.
g. Connect the 2 in. x 10 ft., green-banded suction hose to Adaptor A-05.
0009 00-16