ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0009 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
PREPARATION FOR USE AND INSTALLATION INSTRUCTIONS
COLD WEATHER SET-UP OPERATION UNDER UNUSUAL CONDITIONS
WARNING
Electrical hazard. The TWPS operates on 416 Volts AC. Making electrical
connections to the TWPS power distribution panel must be coordinated with the
procedures for establishing electrical power to the TWPS. Do NOT connect the
Motor-Driven Pump P-2 electrical power cable at this time. Failure to observe this
warning may result in serious injury or death from electrocution.
P-2 PUMP ONLY CONFIGURATION DEPLOYMENT
CAUTION
Potential water damage to equipment. Make note of potential tidal or river flood
conditions and locate the raw water pump to prevent the pump and hose heating
blankets from becoming submerged. Failure to observe this caution may result in
water damage to the pump and motor.
1. Position the raw water pump as follows (see Figure 13):
WARNING
Two person lift. Two people are required to safely lift Motor-Driven Pump Skid P-2.
Lift with your legs, not your back. Failure to observe this warning may result in
back injury.
a. Place a pump insulating platform on the ground where the raw water Motor-Driven Pump
P-2 is to be located.
b. Move Motor-Driven Pump Skid P-2 into place on top of the insulating platform.
A-02
A-01
A-05
2 X 10 S-HOSE
P-2
2 X 50 D-HOSE
Figure 13. P-2 Pump Only Configuration Deployment.
0009 00-17