ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0009 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
PREPARATION FOR USE AND INSTALLATION INSTRUCTIONS
COLD WEATHER SET-UP OPERATION UNDER UNUSUAL CONDITIONS
WARNING
Three person lift. Three people are required to lift Diesel-Driven Distribution Pump
P-8. Lift with your legs, not your back. Failure to observe this warning may result
in back injury.
d. With the engine running at idle, move the pump into place on the insulating platform.
WARNING
Electrical hazard. The hose heating blankets operate on 208 VAC. Complete the
installation of the blankets and connect their power cables to the P-8 pump skid
junction box. Do NOT connect the P-8 pump skid power cable to the TWPS PDP
(power distribution panel) at this time. Failure to observe this warning may result
in serious injury or death from electrocution.
CAUTION
Connector damage or poor electrical connection. Use the fine brush from the tool
box to clean dust and sand out of connectors, terminals and dust caps before
making or capping a connection. Install the dust cap provided with connectors
and terminals whenever a connector is disconnected from its terminal. Failure to
observe this caution may result in connector damage or a poor electrical
connection.
9. Complete the hose and blanket installation (see Figure 32 for heating blanket installation and
connection drawing).
a. Connect the suction hose that extends from Adaptor A-07 to the pump inlet.
b. Make sure that the suction hose heat blanket extends over the exposed couplings.
c. Loosen the pump insulating cover and connect the suction hose heating blanket P04
cable to the P-8 pump junction box.
d. Connect the P03-1 and P03-2 hose heating blanket power cables to the pump junction
box.
e. Connect the pump outlet tee Adaptor A-08 to the pump discharge.
f. Connect the distribution hoses to Adaptor A-08. Pull the blankets over the couplings.
g. Connect the two distribution hose blanket P05 power cables to the pump junction box.
h. Connect the P-8 skid power cable to the P-8 skid junction box. (Feed the cable in under
the pump insulating cover at the front.)
i. Attach the hook and loop strips on the pump insulating cover flaps and pull the bottom
belt tight.
0009 00-43