TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR INSTRUCTIONS
MICRO-FILTRATION SYSTEM CLEANING WITH REVERSE OSMOSIS
SYSTEM ACID CLEANING OPERATION UNDER USUAL CONDITIONS
PRESERVATION
1. Perform the RO preservation procedures as described in WP 0025, RO System Preservation.
2. The MF is preserved as a result of the caustic detergent cleaning steps in this procedure. At the
end of the MF Caustic Detergent Cleaning, the caustic detergent cleaning solution was drained
and then air-purged from the MF modules. The MF modules are NOT rinsed with product water.
Residual caustic detergent cleaning solution left in the MF fibers serves to preserve the fibers
until the next time the TWPS is deployed.