ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0027 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR INSTRUCTIONS
OPERATION UNDER UNUSUAL CONDITIONS
4. Continue with Initial Start-Up or Start-Up with the System Fully Drained (WP 0014)
5. After adjusting the product flow, check the TQG power meter.
a. If 30 kW is available, set the Tank Heater switch to Auto 2.
b. If less than 30 kW but at least 15 kW is available, set the Tank Heater switch to AUTO 1.
c. If less than 15 kW is available, leave the heaters off.
NOTE
In very cold weather the MF modules may shrink and leak. If this happens, place
the TWPS in Short Term Shutdown Cold Weather Operation (refer to WP 0017).
Then torque the 4 nuts at the top and 4 nuts at the bottom of one end of the MF
assembly to 45 to 50 ft. lbs. (see Figure 3).
NUTS
Figure 3. MF Assembly.
0027 00-5