ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0027 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR INSTRUCTIONS
OPERATION UNDER UNUSUAL CONDITIONS
Double Pass NBC Filtration Using One TWPS
1. Wear appropriate protective gear as required.
2. Perform the first filtration pass as follows:
a. Set up the unit for normal operation (WP 0007) except as noted below.
1) Do not set up the NBC filter at this time. Set aside two product hoses (P02) to
connect this filter when it is set up.
2) MC-TWPS: Do not interconnect the two distribution tanks. Connect the product
hose P02 (one or two hoses only) to only one of the two tanks. Connect the
distribution pump to the discharge of the same tank. Physically mark this tank to
identify it as "First Pass Product Water" (see Figure 7).
DISTRIBUTION PUMP P-7
"FIRST PASS PRODUCT WATER"
PRODUCT HOSE P02
2 ONLY
ADAPTOR A-15
DISTRIBUTION TANKS
MC-TWPS
MF FEED TANK
BAG FILTER S-1
WASTE HOSE
MF FEED PUMP P-3
Figure 7. MC-TWPS First Pass Set-Up for Double Pass NBC Filtration Using One TWPS.
0027 00-9