ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0030 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR INSTRUCTIONS
PREPARATION FOR MOVEMENT MARINE CORPS
EXTENDED CAPABILITY MODULES
WARNING
High voltage electrical hazard. High voltage is produced when the generator set is
in operation. Make sure that the Tactical Quiet Generator has been properly shut
down before attempting to disconnect the power or ground cable from the TQG.
Failure to observe this warning could result in injury or death from electrical
shock.
NOTE
Refer to TM 5-6115-545-12 for generator operation.
a. Disconnect the TWPS power cable leads from the generator lugs labeled L1, L2, and L3.
b. Disconnect the TWPS power cable white lead from the generator Neutral lug and the
green lead from the generator Ground lug.
c. Tuck the TWPS power cable end inside the TWPS frame.
d. Disconnect the ground cable from the generator Ground lug.
COLD WEATHER MODULE PACKOUT
Preparation for Cold Weather Module Packout
NOTE
Perform the Preparation for Packout procedures described in WP 0029 for the MC-
TWPS unit at the same time you perform these Preparation for Cold Weather
Module Packout procedures. This helps to ensure that water is drained from all
tanks, pumps, and hoses before the water has a chance to freeze.
Prepare the cold weather module for packout as follows:
1. Sort by length and lay out the following heating blanket hook and loop straps that were stored
when the blankets were installed:
Two 18-in. hook and loop straps
Eight 36-in. hook and loop straps
Ten 48-in. hook and loop straps
2. Remove the raw water, MF feed, and product water distribution pump covers.
CAUTION
Connector damage or poor electrical connection. Use the fine brush from the tool
box to clean dust and sand out of connectors, terminals and dust caps before
capping a connection. Install the dust cap provided with connectors and terminals
whenever a connector is disconnected from its terminal. Failure to observe this
caution may result in connector damage or a poor electrical connection.
3. Disconnect and cap all hose and adaptor heating blankets and pump heating collar power cables.
0030 00-2