ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR INSTRUCTIONS
PREPARATION FOR MOVEMENT MARINE CORPS
EXTENDED CAPABILITY MODULES
INITIAL SETUP:
Reference
TM 10-5430-237-12&P
Personnel Required
Three Operator/Crew
Equipment Condition
TWPS removed from service
GENERAL:
This work package provides instructions for packing out MC-TWPS extended capability module
equipment for movement from one deployed location to another, including short storage periods (up to 30
days) between deployments. Packout instructions are provided for the following Marine Corps extended
capability modules:
Cold Weather Module
Cleaning Waste Storage Module
NBC Water Treatment System Module
NBC Survivability Module
Ocean Intake Structure System (OISS) Module
The extended capability module packout procedures can be performed at the same time that the MC-
TWPS unit is packed out in accordance with WP 0029, Preparation for Movement Marine Corps Unit.
If the TWPS unit will be in storage for more than 30 days, refer to WP 0032, Preparation for Storage
Marine Corps Unit, before performing the packout procedures described in this work package.
UNIT SHUTDOWN AND PRESERVATION
NOTE
These Unit Shutdown and Preservation procedures are also listed in WP 0029,
Preparation for Movement Marine Corps Unit. If you have already performed
these shutdown and preservation procedures, proceed to the desired extended
capability module packout procedures in this work package.
Before starting equipment/component disassembly and packout, the MC-TWPS must be shut down,
flushed and drained, and the power source must be secured and disconnected. Preservation of the
Micro-Filtration (MF) and Reverse Osmosis (RO) elements may also be required based on the expected
length of the shutdown.
1. Refer to WP 0017 and WP 0018 for shutdown and preservation requirements and procedures.
2. Disconnect the power and ground cables from the Tactical Quiet Generator (TQG) as follows:
0030 00-1