ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0048 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
RAW WATER SYSTEM
SCREW (2)
JUNCTION BOX
TERMINAL BOX COVER
GASKET
RING NUT
CABLE
MOTOR
Figure 7. P-2 Pump Electric Motor Cable Replacement.
P-2 Electric Motor-Driven Pump Replacement:
Parts (TM 10-4610-309-24P):
P-2 Pump
Material:
Corrosion Preventive Compound (WP 0079, Table 1, item 17)
Equipment Condition:
P-2 Pump assembly removed from service and drained
Replace the P-2 pump as follows (see Figure 8):
1. Remove the pump as follows:
a. Disconnect the pump motor cable from the junction box.
b. Remove the four bolts and washers that attach the pump/motor unit to the skid.
WARNING
Two person lift. Two people are required to safely move the pump/motor unit. Lift
with your legs, not your back. Failure to observe this warning may result in back
injury.
c. Slide the pump/motor unit out the side of the skid.
d. Remove the six nuts that attach the pump housing to the adapter, then loosen and
remove the pump housing.
e. Remove and discard the coupling clamp assembly.
0048 00-10