Replace the P-7 Pump electric motor as follows (see Figure 4 and Figure 5):
1. Remove the pump motor as follows:
a. Disconnect the motor cable at the skid junction box.
b. Remove the six nuts that attach the pump housing to the adapter.
c. Remove the pump housing and gasket. Discard the gasket.
d. Remove the coupling clamp assembly.
COUPLER AND DUST CAP
IMPELLER
DRIVE SLEEVE ASSEMBLY
COUPLER AND DUST PLUG
PUMP HOUSING
NUT
CAP SCREW AND LOCK WASHER
ADAPTER
MOTOR
DRIVE SHAFT
SET SCREW
COUPLING CLAMP ASSEMBLY
Figure 4. Pump P-7 Electric Motor Replacement.
e. Carefully pry the impeller/drive sleeve assembly off the motor drive shaft.
f. Remove the lock nut and drive sleeve from the impeller (see Figure 5). Discard the
sleeve and the seal assembly. Attach the new sleeve to the impeller using the lock nut.
g. Lubricate the new seal assembly with glycerin. With the rubber boot end toward the
impeller, twist and slide the assembly onto the drive sleeve.
h. Remove the four cap screws and four lock washers that attach the motor to the adapter
and remove the motor.
i. Push the seal seat out of the adapter and discard it.
j. Clean the adapter bore and mounting faces.
k. Clean the new seal seat and lubricate it with glycerin. Insert the beveled end of the seal
seat into the adapter bore and press it into the adapter.
0058 00-8