ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0059 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
OPERATING CONTROL SYSTEM TOP PANEL
OPERATING CONTROL PANEL
PANEL
KNOB
ROTARY SWITCHES
SET
SCREW
RING NUT
WASHER
SHAFT
EMI GASKET
ATTACHMENT
RING NUT
Figure 8. Rotary Switch Assembly Replacement.
2. Install a new rotary switch as follows:
a. Position the new rotary switch in the panel with washer and back ring nut.
b. Position the EMI gasket through the shaft to the panel.
c. Tighten the front ring nut to secure the rotary switch to the panel.
d. Slide the shaft attachment on the shaft and secure with mini screw.
e. Install the new switch knob.
f. Make any adjustments to knob and rotary switch to align with selections on panel.
g. Attach the wires to the screw connections in accordance to the wire tags.
h. Tighten the screw connections to secure the wires.
i. Remove the wire tags if necessary.
j. Reinstall the protective box, close and secure the operating control panel top panel.
Push Button Replacement:
Parts (TM 10-610-309-24P):
Push Button, illuminated, red
Push Button, illuminated, green
Gray Push Button
EMI gasket
Equipment Condition:
Army TWPS: Generator off and TWPS main breaker off
Marine Corps TWPS: TWPS disconnected from power source
0059 00-10