ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0059 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
OPERATING CONTROL SYSTEM TOP PANEL
OPERATING CONTROL PANEL
HOUR METER
NUT
SCREW
WASHER
HOUR METER
PANEL
EMI GASKET
Figure 5. Hour Meter Assembly Replacement .
2. Install the new hour meter as follows:
a. Position the new hour meter and EMI gasket in the panel.
b. Secure the new hour meter to the panel using the three screws, washers, lock washer
and nuts.
c. Connect the connector wires to the blade terminals in accordance to the wire tags.
d. Remove the wire tags if necessary.
e. Reinstall the protective box, close and secure the operating control panel top panel.
Digital Display Replacement:
Parts (TM 10-610-309-24P)
Digital display
Digital display with reset
EMI gasket
Equipment Condition:
Army TWPS: Generator off and TWPS main breaker off
Marine Corps TWPS: TWPS disconnected from power source
Replace a digital display (current condition digital display) on the operating control panel top panel as
follows:
0059 00-6