TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
OPERATING CONTROL SYSTEM SUB PANEL
OPERATING CONTROL SUB-PANEL
DC (40) AND AC (26) TERMINALS
Figure 17. AC or DC Terminal Removal.
4. Install the new AC or DC terminal as follows:
a. Position the new AC or DC terminal on the DIN rail and snap into place.
b. Insert the wires in the screw connections in accordance to the wire tags.
c. Tighten the screw connections to secure the wires.
d. Remove the wire tags if necessary.
e. Close and secure the OCP instrument panel using the 14 screws.
Ground Terminal Replacement:
Parts:
Ground Terminal (TM 10-610-309-24P)
Equipment Condition:
Army TWPS: Generator off and TWPS main breaker off
Marine Corps TWPS: TWPS disconnected from power source
Replace the ground terminal on the operating control panel sub-panel as follows:
1. Open the cover to the OCP (see Figure 1).
2. Remove the 14 screws that secure the OCP and swing the instrument panel open.
3. Remove ground terminal (green/yellow) as follows (see Figure 18):
a. Locate the ground terminal.
b. Tag wires connected to the terminal.
c. Loosen the screw connections and remove the wires.
d. Loosen the center screw on the ground terminal and then lift the terminal off the DIN rail.