ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
FEED FLOW CONTROL PANEL
THIS SECTION COVERS:
Replace
INITIAL SETUP:
Maintenance Level
Unit
Tools
Marine Corps: Common No. 1 Tool Set (WP 0075)
Reference:
Refer to TM 10-4610-309-24P for repair parts information
Personnel Required
One
Equipment Condition
TWPS in Standby Shutdown Without Draining Down
Army TWPS: Generator off and TWPS main breaker off
Marine Corps TWPS: TWPS disconnected from power source
GENERAL:
This work package contains information and instructions for replacing components in the air system feed
flow control panel of the TWPS. If you are unable to return a component or assembly to workable
condition by following the repair procedure, replace the complete panel assembly. The procedures
covered in this work package include, in order:
Air System Bleed Down Procedures
Feed Flow Control Panel Assembly Replacement
Pressure Regulating Valve PRV-904 Replacement
IP Transducer FY-102 Replacement
Three Way Solenoid Valve XV-912 Replacement
Feed Control Selector Valve V-914 Replacement
Pressure Gauge 0-30 psig PI-904 Replacement
All feed flow control panel repair procedures in this work package, can be performed on the TWPS.
0061 00-1