ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0063 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
POWER DISTRIBUTION SYSTEM
DUST COVER
WASHER
SCREW
GASKET
NUT
CONNECTOR
POWER CONNECTORS (5)
POWER DISTRIBUTION BOX
Figure 13. Power Connector Replacement
2. Install new power connector.
a. Position the new gasket through the wires on the distribution box.
b. Strip in. of insulation off the end of each wire.
c. Solder the wires to new connector connecting pins according to wire tags.
d. Align the connector and gasket with the screw holes on the power distribution box.
e. Position the end of dust cover chain on one of the screw holes with the connector and
gasket.
f. Secure the connector, gasket and dust cover chain to the power distribution box using
the four screws, washers and lock nuts.
Light Outlet Assembly Replacement:
Parts (TM 10-610-309-24P):
Light outlet assembly, 5 socket, 16 shell
Light outlet assembly, 3 socket, 16 shell
Gasket, plain
Equipment Condition:
TWPS in Standby Shutdown Without Draining Down
Army TWPS: Generator off and TWPS main breaker off
Marine Corps TWPS: TWPS disconnected from power source
0063 00-24