TM 3-4230-209-10
Item
Location, Item to
Not Fully Mission
No.
Interval
Check/Service
Procedure
Capable If:
BEFORE
b. Check electrolyte level. If
Electrolyte level
and
electrolyte is not filled to ledge
is low.
QUARTERLY
in filler opening, notify unit
maintenance.
BEFORE
c. Check that vent holes in vent
and
caps are clear.
QUARTERLY
BEFORE
d. Inspect frame area terminals,
and
clamps, cables, and hold-
QUARTERLY
downs for corrosion.
9
BEFORE
Gun Assembly
a. See that a gun assembly is on
Gun valves
and Slurry
each of the discharge hoses.
inoperative.
Nozzle
Check that the gun handle
Assembly
operates the valve. Close the
valves.
BEFORE
b. Inspect the gun assembly and
Nozzle is
and
slurry nozzle assembly for dirt
clogged.
QUARTERLY
and hardened slurry. Inspect
the threaded fittings for nicks,
burrs, or other damage.
Inspect the gun handle for
cracks, chips, twists, bends, or
other damage that would
interfere with efficient
operation. Inspect the
extension pipe and adapter for
cracks, bends, holes, being
out of round, or other damage
that would affect operation of
the gun assembly.
QUARTERLY
c. Clean the hardened slurry or
dirt from the gun and slurry
nozzle assembly. Be
especially careful to clean the
hard-to-reach areas around
the gun handle and the
adapter threads.
(1) Thoroughly clean all
nozzles that have been
used to spray liquids other
than water.
(2) Use soapy water and a
small brush to loosen the
dirt. Rinse with clean
water, and dry all parts
thoroughly.
(3) Inspect the gasket for
cuts, wear, and
deformation.
Change 2 2-25