TM 3-4230-209-10
Table 2-2. OPERATOR'S PREVENTIVE MAINTENANCE CHECKS
AND SERVICES (PMCS) (CONT)
Item
Location, Item to
Not Fully Mission
No.
Interval
Check/Service
Procedure
Capable If:
Pump Unit
Assembly
(Cont)
10
BEFORE
Prime-
a. Check that there are no
Foreign objects
Detergent Tank
foreign objects or sediment
or sediment are
Assembly and
in tank. Clean if necessary.
in tank. Tank
Tank Lid
Close VALVE NO. 4 PRIME
leaks
on control panel. Fill tank
continuously.
with water and check for
leaks.
QUARTERLY
b. See that the tank is fastened
to the pump unit. See that
the tank lid is in place.
QUARTERLY
c. Inspect tank lid for cracks
and for loose, missing and
corroded parts.
Change 2 2-26