TM 3-4230-218-12&P
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3.
Check for broken or separated burner lead assembly.
If burner lead choke cable assembly is broken or separated, replace
cable (refer to page 4-54).
If burner lead assembly is not defective, notify direct support
maintenance.
13.
BURNER LIGHTS AND EXTINGUISHES WHEN START BURNER
RELEASED.
Step 1.
Check for dirty mica window.
If window is dirty, clean window (refer to page 4-37).
If window is not dirty, proceed to step 2.
Step 2.
Check for broken or cracked cell.
BUTTON IS
If cell is
If cell is
cracked or broken, replace cell (refer to page 4-37).
not defective, notify direct support maintenance.
14.
OPEN MAG VALVE INDICATOR LIGHT FLUCTUATES.
Step 1.
Check for corroded, cracked, or broken lamp socket or broken
If
If
If
Step 2.
or burned out lamp.
socket is defective, notify direct support maintenance.
lamp is defective, replace lamp (refer to page 4-52).
lamp and socket are not defective, proceed to step 2.
Check for loose wires in cell, magnetic valve, and lamp
circuit.
Tighten all electrical connections including ground wires.
If no loose wires are found, proceed to step 3.
Step 3.
Check for cracked or broken cell.
If cell is cracked or broken, replace cell (refer to page 4-37).
If cell is not defective, notify direct support maintenance.
4-13