2-7.
TM 3-4230-218-12&P
Section III.
OPERATION UNDER USUAL CONDITIONS
Para.
Para.
Assembly and Preparation
Preparation for Move-
for Use . . . . . . . . . ...2-7
merit . . . . . . . . . . . . .2-9
Operating Procedures . . . . . 2-8
Decals and Instruction
Plates . . . . . . . . . . .2-10
NOTE
For unpacking instructions refer to page 4-2.
Assemble shower injector, cleaning wands, or water tank only as required
to support your particular operating mode.
These procedures consist of the following:
Suction Hose Connection (page 2-14).
Branch Hose Connection (page 2-15).
Pressure Hose Connection (page 2-16).
Shower Assembly (page 2-17).
Injector Connection (page 2-18).
Cleaning Wand Connection (page 2-19).
Engine Fueling (page 2-20).
Heater Fueling (page 2-22).
Water Tank Set-Up (page 2-23).
a.
Suction Hose Connection.
(1) Connect suction hose (1) to inlet connection (2) by alining
locking levers (3) straight up and down.
(2) Pull levers straight back to lock
CAUTION
Do not let suction hose strainer rest on bottom
hose into position.
of water source.
Ingestion of
foreign matter can cause damage to the system.
2-14