TM 3-4230-218-12&P
NOTE
Assemble only those parts of your equipment which will be used to support
your operating mode. Shower assembly, injector, and cleaning wand connec-
tions are described on the following pages.
d.
Shower Assembly.
(1) Connect three shower bar sections (1) together. The nozzles
do not have to be lined up.
Offsetting of shower nozzles will
allow for more convenient spray angle. Slide nut over shoulder
of each shower bar section and tighten.
(2) Mount shower bars on a supporting device to hold shower bars
at least
(i. e., a
(3) Connect
in place
seven feet above ground on any support available
tree or post) or as directed by local SOP.
end of pressure nose (2) to shower assembly.
Secure
by turning brass ring (3) fully clockwise.
(4) Repeat above three steps for other shower.
Shower, Assembly.
2-17