TM 3-4230-237-10
0007 00
HEATING WATER FROM THE TANK - Continued
VVALVE NOO. 1
AL VE N . 1
F
MANIFOLD
19
20
11
7
8
2
2. Make sure VALVE NO. 1 on the pump unit is closed.
3. Connect one end of suction hose (2) to tank unit drain valve (7) and other end to suction connection on pump unit (8).
Open tank drain valve (7).
4. Connect one end of blender hose (11) to bottom discharge connection on pump unit and other end to bottom connection
on water heater (19).
5. Connect free end of heater unit water hose (20) to upper discharge piping on pump unit and other end to upper connection
on water heater.