TM 3-4230-237-10
0016 00
OPERATOR'S PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - Continued
Table 1. Before Operation PMCS for M12A1 DED Decontaminating Apparatus - Continued.
3
Procedure
Not Fully
Item
Interval
Man
Item to be
Mission
No.
Hour
Checked/
Capable If:
Serviced
Parts are broken
3
BEFORE
Personnel
a. Inspect the exterior surfaces of the pipes and
or out of round.
Shower
fittings for out of round and broken parts.
Assembly
Holes are clogged.
b. Make sure the shower outlet holes in the six pieces
of pipe are open.
WARNING
Fire and explosion danger exist
when solvent cleaning compound is
used. Make sure that equipment is
dry before operations begin.
c. Remove pipe plug (1) from sediment strainer (2).
Sediment strainer
Remove screen (3) and clean using water, cleaning
is clogged or
solvent, or rag. Reinstall screen (3).
missing.
2
3
1
d. Check for missing or damaged gaskets.
Gaskets are
missing or
damaged.
0016 00-4