TM 5-3800-205-10-2
Table 1. Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
CAB INTE-
RIOR
a. Visually check for missing or dam- a. Fire extinguisher is miss-
24
Before
Fire Extin-
ing or damaged.
guisher
aged fire extinguisher. Ensure it is
securely mounted in bracket
directly behind seat.
b. Check gage for reading in green b. Pressure gage needle is in
area on gage.
red area.
c. Check for damaged or missing seal. c. Seal is broken or missing.
d. Inspect fire extinguisher inspection d. Inspection date is not cur-
tag.
rent and/or tag is missing.
SEAL
GAGE
390-1302
25
Before
Instrument
Check for damaged gages, warning
Any warning indicator is
Panel
indicators, and switches.
broken or unreadable.
Ensure that control panel is securely Damage that would impair
26
Before
Water Dis-
mounted and not damaged. Check that operation is evident.
tributor
electrical and air connections are
Control
secure.
Panel
Seat belt is damaged. Date
27
Before
Seat and
Check seat and seat belt for damage
on belt is more than three
Seat Belt
and proper operation. Ensure seat
years old. Seat will not
adjustments function and seat locks in
adjust/lock in place.
place.
0013 00-25