TM 5-3800-205-10-2
Table 1. Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
71
Weekly
Ether Cold
Start System
WARNING
Ether fuel is extremely flammable and toxic. DO NOT
smoke and make sure you are in a well-ventilated area away
from heat, open flames or sparks. Wear eye protection. Avoid
contact with skin and eyes and avoid breathing ether fumes.
If fluid enters or fumes irritate the eyes, wash immediately
with large quantities of clean water for 15 minutes. Seek
medical attention immediately if ether is inhaled or causes
eye irritation. Failure to follow this warning may cause death
or serious injury to personnel.
a. Check for loose connections and a. Damage or evidence of
leaks are noted. Ether can-
damage to lines, fittings, and ether
ister is missing, if required
canister. Ensure canister is securely
for mission.
mounted. Be alert for odor of leak-
ing ether.
b. Check and install protective cap on
fitting when ether canister is not
installed.
PROTECTIVE CAP
ETHER
(ETHER CANISTER NOT INSTALLED)
CANISTER
390-1716
390-1274
0013 00-55