TM 5-3800-205-10-2
AIR TRANSPORT BY C-130 AIRCRAFT - CONTINUED
0017 00
CONFIGURE MACHINE FOR AIR TRANSPORT - CONTINUED
CAUTION
Always wipe ends clean prior to disconnecting hydraulic lines. Ensure ends are clean prior to reconnecting.
Failure to do so may introduce contamination into hydraulic system.
NOTE
Review all load transfer relief valve and hose assembly installation steps before proceeding, to aid in under-
standing installation steps.
13.
Install load transfer relief valve and hose assembly to tank lift cylinder plumbing and to unused elevator motor drain line
at left side of machine:
a.
Disconnect hose A quick disconnect from tube C. Disconnect hose B quick disconnect from tube D.
HOSE A
TUBE C
HOSE B
TUBE D
0017 00-14