BUTTERFLY VALVE ASSEMBLY INSTALLATION
1.
Ensure valve indicator (3) is in vertical (closed) position.
2.
Position butterfly valve assembly (17) on upper spray bar (16).
16
17
3
3.
Install four bolts (10), new lockwashers (9), and nuts (8) on upper spray bar flanges (11).
4.
Install top half of clamp (15) with two bolts (14), new lockwashers (13), and nuts (12).
NOTE
Clean threads of fittings and apply new tape prior to installation.
5.
Connect two air lines (1) to actuator valve (2) and remove tags.
1
8,9,10
15
12,13,14
11
2