TM 5-3800-205-23-3
UPPER AND LOWER SPRAY BAR REPLACEMENT - CONTINUED
0028 00
UPPER SPRAY BAR INSTALLATION
1.
Apply a thin coat of sealing compound to drain plug and install in pipe (21).
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during proce-
dure. Ensure that any lifting device used is in good condition and of suitable lift capacity. Keep clear of
heavy parts supported only by lifting device. Failure to follow this warning may result in death or injury to
personnel.
2.
Position flanges (11) and clamps (12). Install two bolts (13), flatwashers (14), new lockwashers (19), and nuts (20) to
each clamp.
3.
Install pipe (21) and position lower pipe (6).
4.
Install seal (10) and coupling (9) with two bolts (8) and nuts (7).
5.
Install left and right spray butterfly valve assemblies (WP 0027 00). Install new tiedown straps to secure air hoses to
pipe (21).
6.
Install elbow (4) on each flange (11) with seal (18), coupling (17), two bolts (16), and nuts (15).
7.
Position spray head (1), clamp (2), bolt (3), and handle (5) on each elbow (4).
8.
Tighten handle (5).
9.
10.
Fill tank with water, discharge from upper spray bar, and check for leaks (TM 5-3800-205-10-2).
1
2
3
5
4
0028 00-3