TM 5-3800-205-23-3
WATER PUMP CHECK VALVE ASSEMBLY MAINTENANCE - CONTINUED
0040 00
REMOVAL - CONTINUED
3.
Remove two nuts (7), lockwashers (8), four flatwashers (9), and two bolts (10) from support bracket (12) and water dis-
tributor frame (11). Discard lockwashers.
12
11
7,8,9,10
NOTE
Note position of pipe plug in flange to ensure proper installation.
4.
Remove four bolts (13), lockwashers (14), and support bracket (12). Discard lockwashers.
5.
Remove flange (3) from pump housing (15).
PIPE PLUG
15
3
13,14
12
0040 00-2