TM 5-4610-218-12
Table 4-2.
Troubleshooting-Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3.
Check for defective gages.
12.
PLUG VALVES LEAK OR DRAW AIR.
Step 1.
Check for cracked or broken valve body.
Step 2.
Check for defective packing.
Step 3.
Check for sufficient lubrication.
Lubricate in accordance with LO 5-4610-218-12.
13.
AIR RELEASE VALVE WILL NOT OPERATE.
Step 1.
Check for clogged lines.
Remove and clean the lines.
Step 2.
Check for cracked valve housing.
Step 3.
Check for defective diaphragm or diaphragm spring.
Step 4.
Check for inoperative three-way release valve.
14.
WATER PUMP OPERATION NOISY.
Step 1.
Check to see if impeller mounting shaft is bent.
Replace the shaft.
Step 2.
Check to see if the impeller is loose or shaft is broken.
4-50