TM 55-1930-209-14&P-10
3-14.2.6
Navigation lights
a
Open (OFF) circuit breaker 2P14 on 24 Vdc power panel to turn off navigation lights.
b
Redtag circuit breaker with: "WARNING - DO NOT ACTIVATE - REPAIRS BEING MADE."
c
Remove navigation light cover. Clean with fresh water. Wipe dry.
d
Replace burned-out bulb.
e
Reinstall light cover.
f
Close (ON) circuit breaker 2P14 to make sure bulb works.
g
Remove red tag.
Section V. Storage
3-15
Short-term storage. If barge is taken out of service for more than 7 days but less than 30 days, and exterior
lighting system will not be used while in storage, follow shutdown procedures in paragraph 3-10 Check for corrosion,
damage, and pilferage Correct as necessary.
3-16
Administrative storage. If barge is taken out of service for more than 30 days but less than 6 months, barge
remains a unit responsibility and shall be maintained by unit personnel. Check for corrosion, damage, and pilferage.
Correct as necessary
3-17
Long-term storage. If barge is to be taken out of service for 6 months or more, turn it in to depot for
preparation and placement into long-term storage. If barge is In administrative storage and is to be taken out of service
and placed In depot long-term storage (6 months or more), process exterior lighting system for normal operations as
specified In the following steps before releasing to depot.
a.
Perform before operation checks in Appendix C.
b.
Check that exterior lighting system operates satisfactorily while performing the procedures in paragraphs 3-9 and
3-10.
c.
Perform during operation checks in Appendix C.
3-14