TM 55-1930-209-14&P-15
Table C-1. Preventive Maintenance Checks and Services for Miscellaneous Equipment (Continued)
B - Before
D - Daily
Q - Quarterly
D - During
W - Weekly
S - Semiannually
A - After
M - Monthly
A - Annually
ITEM
PROCEDURES
EQUIPMENT
ITEM
INTERVAL
TO BE
CHECK FOR AND HAVE
IS NOT READY/
NO.
INSPECTED
REPAIRED OR ADJUSTED
AVAILABLE IF
B D A D W M Q S A
AS NECESSARY
4
Sanitation
System
Ship's Toilet
CAUTION
Two toilets are onboard, one forward and
one aft In the ROWPU space. Do not use
toilet when incinerator is full. Always keep
lid closed when toilet is not in use to prevent
anything from dropping into toilet.
a. Wipe components clean and check for
damage. Repair as necessary.
b. Check that bowl wax liners and tissue
paper are available.
c. Make sure incinerator ashpan is not full.
Empty if necessary.
d.
Perform prestart operations:
1) Make sure power panel 3 circuit
breaker 5P13 for forward toilet or
4P13 for aft toilet is closed (ON).
2) Place waxpaper liner in bowl before
using toilet.
CAUTION
The Incinerating toilets will incinerate
human waste, both solids and urine, toilet
paper, and sanitary napkins. Toilets may be
used at any time, even while Incinerating a
prior waste deposit, provided toilet capacity
Is not exceeded. The Incinerating toilet will
NOT Incinerate cans or bottles and should
NOT be used to Incinerate highly com-
bustible products, such as oily rags.
e. After stepping on foot pedal, make sure
incineration cycle starts.
f. Make sure blower comes on.
g. Close incinerating toilet lid after each use.
h. Make sure toilet and cubicle are clean.
C-7