TM 55-1930-209-14&P-15
5-19.2 Bilge system
a.
Perform before operation checks in Appendix C.
b.
Check that equipment operates satisfactorily while performing procedures in paragraphs 5-10.2.
c.
Perform after operation checks in Appendix C.
d.
Upon successful completion of operation, release barge to depot for long-term storage.
Section V. Manufacturers' service manuals/Instructions
5-20 General. Manufacturers' service manuals/instructions listed below provide additional information on the sanitation
systems. A copy of each manual is in Appendix B. It may be necessary to refer to both these manuals/instructions and
the drawings listed in Appendix A while performing the procedures in this volume.
Component
Document title
Manufacturer
Incinerating
Installation Operation
Research Products
toilet
Maintenance: Model
Blankenship
WB/TR-111
Dallas, TX 75220
(215) 358-4238
Sludge tank air escape
Tank Air Escape Valve
Robert H. Wager Co., Inc.
valve 1600T
Model 1600
Passaic Ave.
Chatham, NJ 07928
(201) 635-9200
Strainer, simplex
Hayward Simplex
Hayward Industrial
series # 72
Strainers, Model 72
Products, Inc.
900 Fairmount Ave.
Elizabeth, NJ 07207
Bilge pump
Service Manual, Moyno
Robbins-Myers
35651
SP Pumps, Series 356
Springfield, OH 45501
& 367, Motorized
(800) 845-1310
Section VI. Manufacturers' warranties/guarantees
5-21 General. Information on the warranty/guarantee for bilge system components is provided below:
Component
Manufacturer
Duration
Coverage
Incinerating
Research Products
1 year for all
Materials and
toilet
Blankenship
components except
workmanship
WB/TR-111
Dallas, TX 75220
heater for 6
(215) 358-4238
months
Sludge tank air
Robert H. Wager Co.,
1 year from
Materials and
escape valve
Inc.
date of ship-
workmanship
1600T
Passaic Ave.
ment
Chatham, NJ 07928
(201) 635-9200.
Bilge pump
Robbins-Myers
1 year from
Materials and
35651
Springfield, OH
date of ship-
workmanship
45501
ment
(800) 845-3039
5-32