TM 55-1930-209-14&P-2
Table 4-2. Cooling Pump Motor Controller Troubleshooting (Cont'd)
Problem
Probable Cause
Suggested Action
7
Thermal overload unit
a.
Wrong size heater
a.
Install correct size
8.
Thermal overload unit trips
at too low temperature
a.
Wrong size heater
a.
Install correct size
Table 4-3. Seawater System Troubleshooting
Problem
Probable Cause
Suggested Action
1.
Seawater
pump
1
not
operating
a.
Local START/STOP switch STOP
button depressed (Figure 3-1)
a.
Depress START button
b.
Station on OFF/ON/START in off
position (Figure 4-1)
b.
Start pump
c.
Circuit
breaker
P6
on
main
distribution panel open (OFF)
c.
Close (ON) circuit breaker
d.
Station
OFF/ON/START
local
START/STOP
switches
malfunctioning
d.
Troubleshoot (paragraph 4-7.2.6.2)
e.
Seawater pump malfunctioning
e.
Troubleshoot (Table 4-1)
2.
Seawater
pump
2
not
operating
a.
Local START/STOP switch STOP
button depressed (Figure 4-1)
a.
Depress START button
b.
Station OFF/ON/ START start in
OFF position (Figure 4-1)
b.
Start pump
c.
Circuit
breaker
P7
on
main
distribution panel open (OFF)
c.
Close (ON) circuit
d.
Station OFF/ON/START and/or
local
START/STOP
switches
malfunctioning
d.
Troubleshoot (paragraph 4-7.2.6.2)
e.
Seawater pump malfunctioning
e.
Troubleshoot (Table 4-1)
4-4