TM 55-1930-209-14&P-2
Table 4-3. Seawater System Troubleshooting (Cont'd)
Problem
Probable Cause
Suggested Action
c.
Seawater
pressure
regulator
closed
c.
Open pressure regulator to 10 psi
d.
Seawater
pump
1
or
2
malfunctioning
d.
Troubleshoot (Table 4-1)
e.
In-line filter clogged
e.
Replace filter (paragraph 4-7.2.11)
7.
Seawater
not
being
supplied
to
chlorination
system through the cooling
pump
a.
Valve SW47 closed
a.
Open valve SW47
b.
Seawater strainer clogged
b.
Switch to alternate strainer and clean
clogged strainer (paragraph 4-7.2.3)
c.
Seawater
pressure
regulator
closed
c.
Open pressure regulator to 10 psi
d.
Air conditioning cooling pump
malfunctioning
d.
Troubleshoot (Table 4-1)
e.
Valve(s)
SW3
and/or
SW27
closed
e.
Open valve(s) SW3 and/or SW27
f.
In-line filter clogged
f.
Replace filter (paragraph 4-7.2.11)
g.
Piping clogged
g.
Unclog piping
8.
Seawater
not
being
supplied to air conditioning
unit from cooling pump
a.
Valve SW28 closed
a.
Open valve SW28
b.
Cooling pump malfunctioning
b.
Troubleshoot (Table 4-1)
c. Seawater strainer clogged
c. Switch to alternate strainer and clean
clogged strainer (paragraph 4-1.3)
d.
Valve(s)
SW3
and/or
SW27
closed
d.
Open valve(s) SW3 and/or SW27
e.
Piping clogged
e.
Unclog piping
9.
Seawater
not
being
supplied to ballast tank
a.
Seawater not getting to ballast
tank supply valve SW29
a.
Troubleshoot seawater supply lines as
given in problem 5, a thru e
b.
Piping clogged
b.
Unclog piping
4-6