TM 55-1930-209-14&P-21Table 4-1. Organizational Maintenance Troubleshooting -ContinuedMALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONStep 2. Check for defective battery.Recharge or replace battery.Step 3. Other causes.Notify higher maintenance.12. Ammeter Does Not Register ChargeStep 1. Check for loose electrical connection.Tighten connections or replace wire.Step 2. Check for loose or broken alternator drive belt.Adjust belt tension or replace belt (Para 4-10).Step 3. Test ammeter for proper functioning.Replace a malfunctioning ammeter.13. Winch Drum Brake SlipsStep 1. Check for defective brake band adjustment.Adjust drum brake bands (Para 3-11).Step 2. Check for defective brake linkage adjustments.Adjust brake linkage (Para 3-11).Step 3. Other causes.Notify higher maintenance.14. Winch Drum Clutch SlipsStep 1. Check air system pressure.Correct air system defects.Step 2. Check adjustment.Adjust clutch (Para 3-12).Step 3. Other causes.Notify higher maintenance.4-10