Table C-1. Preventive Maintenance Checks and Services for Shore Discharge System (Continued)
B - Before
D - Daily
Q - Quarterly
D - During
W - Weekly
S - Semiannually
A - After
M - Monthly
A - Annually
Interval
Procedures
Item
Check For And Have
Equipment
Item
To Be
Repaired Or Adjusted
Is Not Ready/
No.
B
D
A
D
W
M
Q
S
A
Inspected
As Necessary
Available If
WARNING
Wear safety glasses when adding
hydraulic fluid. In case of eye contact,
wash with lots of water. In case of skin
contact, wipe and then wash with soap
and water.
1)
Remove filler/breather cap.
2)
Clean filter.
3)
Add Gulf Harmony 46AW or military
equivalent hydraulic fluid until level
gauge indicates 100 percent full.
4)
Replace cap.
5)
Wipe reservoir and immediate area
clean.
6
Hydraulic
Power Unit
Electric Motor
NOTE
Use Mobil Oil Co. Mobilux #2, Shell Oil Co.
Alvania #2, Exxon Beacon 325, Standard Oil
Company of California, Chevron SR1 No. 2,
or some military equivalent lithium-based-
grease unless a special grease is recom-
mended on the motor nameplate.
a.
Lubricate hydraulic power unit electric
motor as follows:
1)
Replace one pipe plug on one end
shield with grease fitting.
2)
Remove other pipe plug for grease
relief.
3)
Using a low-pressure grease, pump in
grease until new grease appears at
grease relief hole.
4)
Remove grease fitting and replace
pipe plug.
5)
Repeat steps a thru d on other end
shield.
6)
After lubricating both end shields,
allow motor to run for 10 minutes
before replacing relief plug.
b.
Lubricate hydraulic power unit motor/
pump coupling as follows:
1)
Remove both grease plugs.
2)
Insert grease fitting in one of the
grease plug holes.
C-5