Item
Procedure
Lube
Page
Every 500 Service Meter Units
(15)
Engine Crankcase(2)
Naturally Aspirated engines-Change
CD
50
oil and filter Clean the engine
breather.
(16) Fan Bearing
Lubricate 1 fitting
MPG
50
(16A)
Fuel System
Clean primary fuel filter and change final
50
Sleeve Metering System
fuel filter.
New Scroll Fuel System
Every 1000 Service Meter Units
(17)
Woodward PSG Governor
Lubricate 2 fittings
MPG
51
Synchronizing Motor
Oil
CD
51
(18)_Shutoff Controls
Have operation checked by Caterpillar
dealer
51
(19) Tachometer Drive
Lubricate 1 fitting
MPG
52
Every 2000 Service Meter Units
(20)
Engine Valve Lash
Measure-Adjust if necessary Ob-
53
serve rotation of valves with engine
idling.
(21) Cooling System
Change antifreeze solution
57
(1)
Service intervals may be shortened in dusty
operating condi tions. I the exhaust smoke
and/or loss of power continues after servicing
the air cleaner, discard that element and in stall
a new element. Install a new element at least
once a year.
(2)
The percentage of sulfur in the fuel will affect the
engine oil recommendations. If the fuel has over
0.5% sulfur content, the CD engine oil must have
a TBN of 20 times the percent age of fuel sulfur
(TBN as measured by the ASTM D-2896
method). If the sulfur content is greater than
1.5%, consult your Caterpillar dealer for correct
engine oil recommendations.
27