TM 55-2090-201-14&P
3-22.
CONDUIT, CONNECTORS AND WIRING, TYPE A AND B SEPARATORS
(Continued).
LOCATION
ITEM
ACTION
R E M A R K S
h.
Install conduit (21) onto
pulling elbow (36) using
connector (20).
Install
other end of conduit into
tee (22) using connector
(19).
i.
Insert nipple (18) into
opening of 1st stage oi1
discharge valve baseplate
and secure with locknuts
(17). Install pulling
elbow (15) onto nipple
(18) using locknut (16).
j.
Install nipple (14) into
elbow (15) using locknut
(13). Install pulling
elbow (11) onto nipple
(14) using locknut (12).
k. Install nipple (9) in
elbow (11) using locknut
(10). Insert end of tee
(8) into opening in 1st
stage sensor and secure
with locknut (7).
l.
Install nipple (6) in tee
(8) and tee (5) onto nip-
ple (6).
m. Install conduit (4) into
tee's (22) and (5) using
connectors (3) and (2).
Install connector (1) into
tee (5).
3-126