TM 55-2090-201-14&P
3-22.
CONDUIT, CONNECTORS AND WIRING, TYPE A AND B SEPARATORS
(Continued).
L O C A T I O N
ITEM
A C T I O N
R E M A R K S
9.
Supply
a. Insert wiring and cable
pump
(30) into tee (12) and
motor
secure by tightening col-
leads
lar (29).
(27)
b. Install connectors (28) to
secure leads (27).
10.
11.
12.
13.
14.
Solenoid
Thread coil leads (22) thru
valve
pulling elbow (25 and 31) and
coil
tee (11).
Place coil (26)
over end of sub-base assembly
(32).
Install locknut (24)
on elbow (25).
Install con-
nectors (23) on leads (22).
NOTE
Install other two (2) solenoid valve coils in the
same manner.
Pulling
Position gasket (21) in place
elbow
and install cover (20) using
cover
screws (19).
(20)
NOTE
Install covers on other five (5) elbows in same
manner.
Solenoid
Position housing (15) and
valve
nameplate (14) in place on
housing
solenoid valves (16, 17 and
(15)
18) and secure with retaining
cap (13).
Tee
Position gasket (8) in place
Covers
on tee cover and install
(9, 10,
cover (7) using screw (6).
11, and
12)
Mini-
a. Reconnect terminals (4) to
probe
2nd stage and prefilter
covers
miniprobes.
(2 and 5)
3-128