TM 10-4610-215-24
TM 08580A-24/2
(3) To remove reservoir to air chamber assemblies tubing (figure 2-33), perform the following:
(a) Remove nuts (1) and clamps (2) securing tubing sections (3), (4), and (5) to trailer frame (6).
(b) Disconnect tubing section (3) from reservoir (7) and tee (8) by removing nuts (9) and sleeves
(10)
(c) Disconnect tubing sections (4) and (5) from tees (8) and (11) and anchor tees (12) by removing
nuts (13) and sleeves (14), then remove tubing section (4).
(d) Disconnect tubing section (15) from tees (8) and (11) by removing nuts (16) and sleeves (17),
then remove tee (8).
(e) Disconnect tubing section (18) from tee (11) and relay valve (19) by removing nuts (20) and
sleeves (21 ), then remove tubing section (18) and tee (11).
(f) Remove tubing sections (3), (5) and (15) and grommets (22) from trailer frame (6).
(g) Remove grommets (22) from tubing sections (3), (5), and (15) .
(h) Remove conduit (23) from tubing sections (3), (4), (5), (15), and (18).
b. Inspection. Inspect all tubing for bends or cracks. Replace tubing, if bends or cracks are found.
c. Installation.
(1) To install reservoir to air chamber assemblies tubing (figure 2-33), perform the following:
(a) Install conduit (23) on tubing sections (3), (4), (5), (15), and (18).
(b) Install grommets (22) on tubing sections (3), (5), and (15).
(c) Position tubing sections (3), (5), and (15) and grommets (22) in trailer frame (6).
(d) Install tee (11) on tubing section (18) using nut (20) and sleeve (21). Connect opposite end of
tubing section (18) to relay valve (19) using nut (20) and sleeve (21).
(e) Connect tubing section (15) to tee (11) using nut (16) and sleeve (17).
(f) Install tee (8) on tubing section (15) with nut (16) and sleeve (17).
(g) position tubing sections (4) and (5) between tees (8) and (11) and anchor tees (12), then connect
using nuts (13) and sleeves (14).
(h) Position tubing section (3) between reservoir (7) and tee (8), then connect using nuts (9) and
sleeves (10).
(i) Install clamps (2) on tubing sections (3), (4) and (5) and secure to trailer frame (6) with nuts (1).
(2) To install the sections of tubing between the air cleaner assemblies and the relay valve (figure 2-32),
perform the following:
(a) Install conduit (10) on tubing (3), then install grommets (9) on tubing (3).
(b) Position tubing (3) and grommets (9) in trailer frame (4).
(c) Connect tubing (3) to air cleaner assemblies (5) and relay valve (6) with nuts (7) and sleeves (8).
(d) Install clamps (2) on tubing (3) and secure to trailer frame (4) with nuts (1).
2-56