TM 10-4610-215-24
TM 08580A-24/2
(4) Replace high-pressure switch assemblies that are damaged beyond repair.
g. Reassembly. (Figure 3-14)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Hold cover (28) and gasket (29) in place and align mounting holes.
Install two screws (30) through cover (28), gasket (29), and switch case (4).
Install surge dampener (27) in bourdon tube (11).
Hold terminal block (5) in place on switch case (4) and align mounting holes.
Install two screws (26) through terminal block (5) and switch case (4).
Install ground screw (31) in switch case (4).
Hold insulator (24), switch (25), and switch bracket (18) in place and align mounting holes.
Install two screws (23) in switch bracket (1 8), switch (25), and insulator (24).
Install two lockwashers (22) and two nuts (21) on screws (23).
(10) Hold bracket clamp (20) and switch assembly (25) in place on bracket (12) and align mounting holes.
(11 ) Install two screws (19) in top of bracket (12) and bracket clamp (20).
(12) Install adjusting screw (16) through switch bracket (18), spring (17), bracket (12), and nut (33). Adjust
to actuate switch.
(13) Hold contact bracket (15) in place on bourdon tube (11) and align mounting holes.
(14) Install two screws (13) in contact bracket (15) and bourdon tube (11).
(15) Place switch assembly (25) into bourdon tube assembly (11) and align mounting holes.
(16) Install two screws (10) through bourdon tube assembly (11) and switch assembly (25).
(17) Install socket gasket (14) on bourdon tube assembly (1 1).
(18) From inside switch case (4), carefully install bourdon tube assembly (11) into switch case mounting
hole.
3-73